Introducing ISO 13849-1, Reliability of Safety Related Parts of Control Systems


This show was recorded live at the 2007 CSA/RIA Robotic Safety Conference in Toronto, Ontario in March, 2007.

Doug discusses the basic elements of the 2006 edition of ISO 13849-1 during a presentation given during the 2007 CSA/RIA Robotic Safety Conference in Toronto, Ontario. The presentation introduces Performance Levels (PL and PLr), Diagnostic Coverange (DC) and Common Cause Failures (CCF).

Learn the meaning of MTTFd, B10 and B10d and their significance in the design of safety systems for machinery.

This show runs 50:22.

Machinery Safety 101 Podcast
Episode V2N3, ISO 13849-1, Reliability of Safety Related Parts of Control Systems

This show was recorded live at the 2007 CSA/RIA Robotic Safety Conference in Toronto, Ontario in March, 2007 by the Canadian Standards Association and the Robotic Industries Association .

Doug discusses the basic elements of the 2006 edition of this important standard, including the introduction of Performance Levels (PL and PLr), Diagnostic Coverange (DC) and Common Cause Failures (CCF). Learn the meaning of MTTFd, B10 and B10d and their significance in the design of safety systems for machinery.

The accompanying PowerPoint presentation can be downloaded from the Machinery Safety 101 blog , http://www.machinerysafety101.com/

Contact Doug Nix by emailing him at dnix@ieee.org or dougnix@machinerysafety101.com or by calling him at (519) 729-5704.

Download the MP3

Download the PowerPoint Presentation Whats New in ISO 13849-1.pps

or the PDF Slides.
Whats New in ISO 13849-1.pdf

Posted: Mon - April 2, 2007 at 01:24 PM          


©